Sign In
Account
-
Safe payment options
We only work with the most secure payment systems.
-
Product return within 30 days
We do our very best to keep our customers happy.
2
1 × $2,304.00
Subtotal: $69,264.00
Shop
“Rosemount 2051CD – 2051CD4F22A1JH3B3L4M5” has been added to your cart. View cart
Showing 761–780 of 1690 results
BY BRANDS
- GE Panametrics (6)
- Panametrics (3)
- Rosemount (1681)
Copyright 2026 © CalibrationSale. All right reserved.
Rosemount 2051CD – 2051CD4A33A1JH7B4KCL4M5
Rosemount 2051CD - 2051CD4A33A1JH7B4KCL4M5 Accelerates deployment in explosive atmospheres via Coplanar SST mounting and HART architecture, maintaining metrology-grade signal integrity for critical 300 psi industrial differential pressure audits.
- Calibrated Range: -300 to 300 psi
- Tolerance Metric: ±0.065% span accuracy
- Output Logic: 4–20 mA HART protocol
- Support Frame: B4 Coplanar SST Bracket
- Voltage Input: 10.5–42.4 Vdc supply
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4A33A1JH7B4L4M5
Rosemount 2051CD - 2051CD4A33A1JH7B4L4M5 Facilitates high-fidelity site verification for safe area process loops, leveraging Coplanar SST mounting and integrated LCD diagnostics to maintain stable 300 psi differential pressure acquisition.
- Display Spec: Local LCD integrated display
- Linearity Spec: ±0.065% span accuracy
- Output Logic: 4–20 mA HART protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Operating Volts: 10.5–42.4 Vdc supply
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B1I1L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B1I1L4M5 Facilitates high-fidelity flow monitoring in hazardous pipe loops, leveraging digital Fieldbus connectivity and integrated LCD diagnostics to eliminate measurement drift and signal attenuation.
- Sensing Limits: -300 to 300 psi
- Linearity Spec: ±0.065% span accuracy
- Output Logic: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Operating Volts: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B1K5L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B1K5L4M5 Optimizes NIST-traceable site verification for pipe-mounted hazardous loops, providing high-fidelity 300 psi differential pressure acquisition through dual-certified digital Fieldbus Link connectivity.
- Operation Span: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B1KCL4M5
Rosemount 2051CD - 2051CD4F22A1JH3B1KCL4M5 Optimizes NIST-traceable site verification for pipe-mounted hazardous loops, providing high-fidelity 300 psi differential pressure acquisition through dual-certified digital Fieldbus Link connectivity.
- Operation Span: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B1L4M5
Rosemount 2051CD4F22A1JH3B1L4M5 resolves industrial high-pressure DP monitoring drift via traditional pipe mounting and local LCD monitoring to maintain robust plant synchronization in safe areas.
- Measurement Type: Range 4 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Stability Rating: ±0.1% URL for 3 years
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B2I1L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B2I1L4M5 Accelerates deployment in panel-mounted explosive atmospheres via dual-certified Fieldbus architecture, maintaining metrology-grade signal integrity for critical 300 psi process loop audits.
- Calibrated Range: -300 to 300 psi
- Tolerance Metric: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Mounting Hardware: B2 Panel Mounting Bracket
- Voltage Input: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B2K5L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B2K5L4M5 Resolves signal attenuation in panel-mounted hazardous zones via FOUNDATION Fieldbus integration, ensuring metrology-grade 300 psi differential monitoring for critical process automation infrastructures.
- Sensing Limits: -300 to 300 psi
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Fixture Type: B2 Panel Mounting Bracket
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B2KCL4M5
Rosemount 2051CD - 2051CD4F22A1JH3B2KCL4M5 Resolves signal attenuation in panel-mounted hazardous zones via FOUNDATION Fieldbus integration, ensuring metrology-grade 300 psi differential monitoring for critical process automation infrastructures.
- Sensing Limits: -300 to 300 psi
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Mounting Hardware: B2 Panel Mounting Bracket
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B2L4M5
Rosemount 2051CD4F22A1JH3B2L4M5 eliminates mid-to-high range differential sensing drift in aggressive media through panel-mounted hardware and an integrated LCD display for high-fidelity industrial process diagnostics.
- Measurement Type: Range 4 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B2 Traditional Panel Bracket
- Power Supply: 9–32 Vdc (Bus-Powered)
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B3I1L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B3I1L4M5 Optimizes NIST-traceable site verification for high-pressure 300 psi loops, providing high-fidelity differential monitoring through Alloy C-276 wetted parts to secure long-term signal stability.
- Operation Span: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Fixture Type: B3 Traditional Flat Bracket
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B3K5L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B3K5L4M5 Streamlines digital integration within hazardous 300 psi infrastructures, providing high-fidelity differential sensing through dual-certified Fieldbus connectivity and traditional flat mounting for regulatory plant audits.
- Pressure Band: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B3KCL4M5
Rosemount 2051CD - 2051CD4F22A1JH3B3KCL4M5 Streamlines regulatory audit compliance for high-pressure hazardous infrastructures, providing metrology-grade differential monitoring with high-density Coplanar architecture to secure signal integrity for 300 psi industrial loops.
- Pressure Band: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B3L4M5
Rosemount 2051CD4F22A1JH3B3L4M5 overcomes high-pressure differential tracking bottlenecks via flat traditional mounting and local LCD monitoring to ensure robust diagnostics in safe plant zones.
- Measurement Type: Range 4 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B3 Traditional Flat Bracket
- Local Interface: M5 LCD Display
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B4I1L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B4I1L4M5 Resolves signal attenuation in intrinsically safe loops via Coplanar SST mounting, ensuring metrology-grade 300 psi differential monitoring for high-fidelity process automation and signal integrity.
- Sensing Limits: -300 to 300 psi
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Support Frame: B4 Coplanar SST Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B4K5L4M5
Rosemount 2051CD - 2051CD4F22A1JH3B4K5L4M5 Optimizes signal integrity in explosive atmospheres via dual-certified Fieldbus architecture and Coplanar SST mounting, securing metrology-grade 300 psi differential sensing for critical process automation loops.
- Operation Span: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Display Spec: Local LCD integrated display
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B4KCL4M5
Rosemount 2051CD - 2051CD4F22A1JH3B4KCL4M5 Accelerates deployment in explosive atmospheres via dual-certified Fieldbus architecture and Coplanar SST mounting, maintaining metrology-grade signal integrity for critical 300 psi process loop audits.
- Calibrated Range: -300 to 300 psi
- Tolerance Metric: ±0.065% span accuracy
- Signal Protocol: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Voltage Input: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F22A1JH3B4L4M5
Rosemount 2051CD4F22A1JH3B4L4M5 Streamlines digital integration within general-purpose infrastructures using FOUNDATION Fieldbus connectivity to maximize data throughput for high-capacity 300 psi process monitoring.
- Calibrated Range: -300 to 300 psi
- Tolerance Metric: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1AH3B1I1L4
Rosemount 2051CD4F33A1AH3B1I1L4 resolves industrial high-pressure DP monitoring drift via traditional pipe mounting and high-durability Alloy C-276 construction to maintain digital precision in hazardous zones.
- Measurement Type: Range 4 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Communication Protocol: FOUNDATIONâ„¢ Fieldbus
$2,304.00
$2,304.00
BY BRANDS
- GE Panametrics (6)
- Panametrics (3)
- Rosemount (1681)