Sign In
Account
-
Safe payment options
We only work with the most secure payment systems.
-
Product return within 30 days
We do our very best to keep our customers happy.
7
1 × $275.00
1 × $2,304.00
Subtotal: $404,296.00
Shop
“Rosemount 2051CD – 2051CD4F33A1JH2B1I1L4M5” has been added to your cart. View cart
Showing 821–840 of 1690 results
BY BRANDS
- GE Panametrics (6)
- Panametrics (3)
- Rosemount (1681)
Copyright 2026 © CalibrationSale. All right reserved.
Rosemount 2051CD – 2051CD4F33A1AH7B3KCL4M5
Rosemount 2051CD4F33A1AH7B3KCL4M5 resolves industrial differential tracking hurdles through flat traditional mounting and dual hazardous area compliance to ensure safe pressure handling in explosion-prone environments.
- Measurement Type: Range 4 Differential (±300 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B3 Flat Bracket
- Stability Rating: ±0.1% URL for 3 years
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1AH7B3L4M5
Rosemount 2051CD4F33A1AH7B3L4M5 resolves standard steam or fluid flow hurdles via B3 flat-bracket pipe mounting and capacitive sensing to maintain non-hazardous process measurement stability.
- Measurement Type: Range 4 Differential (±300 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: 316L SST Diaphragm / SST Flange
- Stability Rating: ±0.125% URL for 5 years
- Mounting: B3 Flat Bracket (2-in Pipe)
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1AH7B4I1L4M5
Rosemount 2051CD4F33A1AH7B4I1L4M5 eliminates aggressive process media monitoring drift via ATEX-certified high-pressure sensing and Coplanar bracket integration to ensure distributed control reliability.
- Measurement Type: Range 4 Differential
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B4 Coplanar Bracket
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1AH7B4K5L4M5
Rosemount 2051CD4F33A1AH7B4K5L4M5 eliminates high-pressure differential monitoring bottlenecks through Coplanar integration and FM safety compliance to ensure reliability in corrosive hazardous zones.
- Measurement Type: Range 4 Differential
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B4 Coplanar Bracket
- Certification: FM K5 (USA)
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1AH7B4KCL4M5
Rosemount 2051CD4F33A1AH7B4KCL4M5 eliminates high-pressure monitoring drift in corrosive streams through FOUNDATION Fieldbus integration and Coplanar flange hardware to maintain dual FM/CSA hazardous area safety.
- Measurement Type: Range 4 Differential (±300 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276
- Communication: FOUNDATION Fieldbus
- Mounting: B4 Coplanar Bracket
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1AH7B4L4M5
Rosemount 2051CD4F33A1AH7B4L4M5 eliminates high-pressure monitoring bottlenecks for heavy corrosive streams through FOUNDATION Fieldbus integration and B4 coplanar mounting to deliver advanced system diagnostics.
- Measurement Type: Range 4 Differential
- Accuracy Statement: ±0.065% of Span
- Measurement Range: ±300 psi
- Wetted Materials: Hastelloy C-276
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B1I1L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B1I1L4M5 Accelerates deployment in pipe-mounted hazardous loops by leveraging high-density Alloy C-276 wetted parts and Fieldbus architecture to eliminate measurement drift in 300 psi systems.
- Calibrated Range: -300 to 300 psi
- Tolerance Metric: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Voltage Input: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B1K5L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B1K5L4M5 Optimizes NIST-traceable site verification for pipe-mounted hazardous loops, providing high-fidelity 300 psi differential pressure acquisition through dual-certified digital Fieldbus Link connectivity.
- Operation Span: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B1KCL4M5
Rosemount 2051CD - 2051CD4F33A1JH2B1K5L4M5 Optimizes NIST-traceable site verification for pipe-mounted hazardous loops, providing high-fidelity 300 psi differential pressure acquisition through dual-certified digital Fieldbus Link connectivity.
- Operation Span: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B1L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B1L4M5 Facilitates high-fidelity digital integration for pipe-mounted process loops, leveraging robust bracket hardware and Alloy C-276 wetted parts to eliminate measurement drift in 300 psi infrastructures.
- Calibrated Range: -300 to 300 psi
- Linearity Spec: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Operating Volts: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B2I1L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B2I1L4M5 Optimizes NIST-traceable site verification in panel-mounted explosive zones, utilizing an integrated LCD interface and Fieldbus connectivity to secure robust 300 psi signal integrity.
- Operation Span: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Mounting Hardware: B2 Panel Mounting Bracket
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B2K5L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B2K5L4M5 Resolves signal attenuation in panel-mounted hazardous zones via dual-certified Fieldbus architecture, ensuring metrology-grade 300 psi differential monitoring for critical process automation infrastructures.
- Pressure Band: -300 to 300 psi
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Fixture Type: B2 Panel Mounting Bracket
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B2KCL4M5
Rosemount 2051CD - 2051CD4F33A1JH2B2K5L4M5 Resolves signal attenuation in panel-mounted hazardous zones via FOUNDATION Fieldbus integration, ensuring metrology-grade 300 psi differential monitoring for critical process automation infrastructures.
- Sensing Limits: -300 to 300 psi
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Fixture Type: B2 Panel Mounting Bracket
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B2L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B2L4M5 Accelerates deployment in panel-mount safe area configurations via digital Fieldbus connectivity, maintaining metrology-grade signal integrity for critical 300 psi industrial differential pressure monitoring audits.
- Operation Span: -300 to 300 psi
- Tolerance Metric: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Mounting Hardware: B2 Panel Mounting Bracket
- Voltage Input: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B3I1L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B3I1L4M5 Resolves signal attenuation in flat-mounted intrinsically safe loops via digital Fieldbus architecture, ensuring metrology-grade 300 psi differential monitoring for critical process automation infrastructures.
- Sensing Limits: -300 to 300 psi
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Display Spec: Local LCD integrated display
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B3K5L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B3K5L4M5 Streamlines digital integration within hazardous infrastructures via dual-certified Fieldbus architecture and flat mounting, providing high-fidelity 300 psi differential sensing for critical process monitoring.
- Pressure Band: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B3KCL4M5
Rosemount 2051CD - 2051CD4F33A1JH2B3KCL4M5 Streamlines digital integration within hazardous infrastructures via flat mounting and dual-certified Fieldbus connectivity, providing robust 300 psi differential monitoring for critical site verification workflows.
- Pressure Band: -300 to 300 psi
- Accuracy Grade: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B3L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B3L4M5 Optimizes NIST-traceable site verification for flat-mounted general-purpose infrastructures, providing high-fidelity 300 psi differential pressure acquisition through local LCD diagnostics and digital Fieldbus architecture.
- Display Spec: Local LCD integrated display
- Accuracy Grade: ±0.065% span accuracy
- Signal Protocol: FOUNDATION Fieldbus protocol
- Fixture Type: B3 Traditional Flat Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B4I1L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B4I1L4M5 Resolves signal attenuation in intrinsically safe loops via Coplanar SST mounting, ensuring metrology-grade 300 psi differential monitoring for high-fidelity process automation and signal integrity.
- Sensing Limits: -300 to 300 psi
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Support Frame: B4 Coplanar SST Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD4F33A1JH2B4K5L4M5
Rosemount 2051CD - 2051CD4F33A1JH2B4K5L4M5 Accelerates deployment in explosive atmospheres via Coplanar SST mounting and Fieldbus architecture, maintaining metrology-grade signal integrity for critical 300 psi industrial differential pressure audits.
- Calibrated Range: -300 to 300 psi
- Tolerance Metric: ±0.065% span accuracy
- Signal Protocol: FOUNDATION Fieldbus protocol
- Support Frame: B4 Coplanar SST Bracket
- Voltage Input: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
BY BRANDS
- GE Panametrics (6)
- Panametrics (3)
- Rosemount (1681)