Rosemount 2051CD – 2051CD3F22A1JH3B3L4M5
Rosemount 2051CD3F22A1JH3B3L4M5 resolves mid-range industrial flow monitoring hurdles through flat traditional mounting and Fieldbus control to maintain standard process integrity.
- Measurement Type: Range 3 Differential
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting: B3 Flat Bracket
- Stability Rating: ±0.1% URL for 3 years
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F22A1JH3B4I1L4M5
Rosemount 2051CD3F22A1JH3B4I1L4M5 overcomes mid-range sensing drift via Coplanar bracket integration and ATEX intrinsic safety to deliver reliable Fieldbus signal tracking.
- Measurement Type: Range 3 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting: B4 Coplanar Flange Bracket
- Certification: ATEX Intrinsic Safety (I1)
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F22A1JH3B4K5L4M5
Rosemount 2051CD3F22A1JH3B4K5L4M5 optimizes mid-range DP monitoring through integrated Coplanar mounting and FM explosion-proof standards to ensure precise tracking in standard Fieldbus process loops.
- Measurement Type: Range 3 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting: B4 Coplanar Flange Bracket
- Communication Protocol: FOUNDATIONâ„¢ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F22A1JH3B4KCL4M5
Rosemount 2051CD3F22A1JH3B4KCL4M5 resolves mid-range industrial flow tracking hurdles via Coplanar mounting and dual FM/CSA certifications to maintain signal integrity in volatile Fieldbus loops.
- Measurement Type: Range 3 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting Hardware: B4 Coplanar Flange
- Communication Protocol: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F22A1JH3B4L4M5
Rosemount 2051CD3F22A1JH3B4L4M5 eliminates mid-range differential sensing drift via Coplanar integration and native FOUNDATION Fieldbus control to ensure accurate digital monitoring in standard flow loops.
- Measurement Type: Range 3 Differential
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting: B4 Coplanar Bracket
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B1I1L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B1I1L4M5 Facilitates NIST-traceable pipe-mount sensing in volatile loops, integrating Alloy C-276 wetted parts to maintain superior signal integrity and long-term stability against process drift.
- Sensing Limits: -1000 to 1000 inH2O
- Linearity Spec: ±0.065% span accuracy
- Output Logic: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Operating Volts: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B1K5L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B1K5L4M5 Resolves installation drift in pipe-mounted hazardous loops by leveraging robust 2-inch bracket hardware and Alloy C-276 wetted parts for enhanced manifold testing reliability.
- Sensing Limits: -1000 to 1000 inH2O
- Precision Rating: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Fixture Type: B1 2-in Pipe Bracket
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B1KCL4M5
Rosemount 2051CD - 2051CD3F33A1AH3B1KCL4M5 Facilitates high-fidelity flow monitoring in hazardous pipe loops, leveraging robust 2-inch bracket hardware and Alloy C-276 wetted parts to eliminate measurement drift and signal attenuation.
- Calibrated Range: -1000 to 1000 inH2O
- Linearity Spec: ±0.065% span accuracy
- Output Logic: FOUNDATION Fieldbus protocol
- Support Frame: B1 2-in Pipe Bracket
- Operating Volts: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B1L4M5
Rosemount 2051CD3F33A1AH3B1L4M5 resolves industrial pressure tracking bottlenecks through traditional pipe mounting and an integrated LCD display to deliver robust Fieldbus diagnostics in safe process loops.
- Measurement Type: Range 3 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Stability Rating: ±0.1% URL for 3 years
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B2I1L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B2I1L4M5 Accelerates workflow efficiency in panel-mounted intrinsically safe environments, utilizing a high-density digital link to eliminate measurement drift during rigorous industrial manifold testing.
- Calibrated Range: -1000 to 1000 inH2O
- Tolerance Metric: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Mounting Hardware: B2 Panel Mounting Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B2K5L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B2K5L4M5 Streamlines digital integration within panel-mounted hazardous infrastructures, utilizing integrated LCD feedback and Fieldbus connectivity to eliminate measurement drift in 1000 inH2O differential pressure loops.
- Display Spec: Local LCD integrated display
- Accuracy Grade: ±0.065% span accuracy
- Signal Protocol: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B2KCL4
Rosemount 2051CD3F33A1AH3B2KCL4 resolves mid-range DP monitoring hurdles through panel-mounted hardware and Fieldbus distributed control to maintain signal integrity in hazardous FM/CSA zones.
- Measurement Type: Range 3 Differential (±1000 inH2O)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276
- Mounting: B2 Panel Bracket
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B2KCL4M5
Rosemount 2051CD - 2051CD3F33A1AH3B2KCL4M5 Accelerates deployment in panel-mounted explosive atmospheres via integrated LCD diagnostics and Fieldbus architecture, maintaining critical signal integrity for rigorous industrial manifold testing audits.
- Display Spec: Local LCD integrated display
- Tolerance Metric: ±0.065% span accuracy
- Bus Network: FOUNDATION Fieldbus protocol
- Mounting Hardware: B2 Panel Mounting Bracket
- Voltage Input: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B2L4M5
Rosemount 2051CD3F33A1AH3B2L4M5 overcomes industrial differential sensing hurdles in non-hazardous zones via panel-mounted hardware and high-durability Alloy C-276 construction for reliable signal tracking.
- Measurement Type: Range 3 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B2 Traditional Panel Bracket
- Local Interface: M5 LCD Display
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B3I1L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B3I1L4M5 Optimizes hydrostatic head measurement reliability in hazardous plant zones using digital Fieldbus architecture to streamline site verification audits for 1000 inH2O differential applications.
- Operation Span: -1000 to 1000 inH2O
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Fixture Type: B3 Traditional Flat Bracket
- Voltage Input: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B3K5L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B3K5L4M5 Facilitates hydrostatic head measurement reliability in explosive zones via traditional flat mounting and digital Fieldbus Link, providing superior 1000 inH2O differential sensing for regulatory audits.
- Sensing Limits: -1000 to 1000 inH2O
- Linearity Spec: ±0.065% span accuracy
- Output Logic: FOUNDATION Fieldbus protocol
- Mounting Hardware: B3 Traditional Flat Bracket
- Operating Volts: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B3KCL4M5
Rosemount 2051CD - 2051CD3F33A1AH3B3KCL4M5 Optimizes NIST-traceable site verification for high-capacity 1000 inH2O loops, providing high-fidelity differential pressure acquisition through traditional flat mounting and dual-certified digital Link connectivity.
- Operation Span: -1000 to 1000 inH2O
- Accuracy Grade: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Fixture Type: B3 Traditional Flat Bracket
- Excitation Power: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B3L4M5
Rosemount 2051CD3F33A1AH3B3L4M5 eliminates mid-range DP monitoring drift through flat traditional mounting and local LCD monitoring to ensure robust plant synchronization in safe areas.
- Measurement Type: Range 3 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B3 Traditional Flat Bracket
- Local Interface: M5 LCD Display
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B4I1L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B4I1L4M5 Streamlines digital integration within intrinsically safe loops by leveraging Coplanar SST mounting for enhanced mechanical stability and 1000 inH2O differential sensing precision.
- Sensing Limits: -1000 to 1000 inH2O
- Precision Rating: ±0.065% span accuracy
- Data Link: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Energy Source: 9–32 Vdc bus-powered
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD3F33A1AH3B4K5L4M5
Rosemount 2051CD - 2051CD3F33A1AH3B4K5L4M5 Facilitates hydrostatic head measurement reliability in volatile environments, providing superior 1000 inH2O differential sensing through intrinsically safe Coplanar technology and digital Fieldbus Link connectivity.
- Sensing Limits: -1000 to 1000 inH2O
- Linearity Spec: ±0.065% span accuracy
- Output Logic: FOUNDATION Fieldbus protocol
- Wetted Part: Alloy C-276 Coplanar Flange
- Operating Volts: 9–32 Vdc bus-powered
$2,304.00
$2,304.00