Rosemount 2051CG – 2051CG5F33A1AH3B2K5L4M5
Rosemount 2051CG5F33A1AH3B2K5L4M5 eliminates high-pressure aggressive fluid drift via panel-mounted wetted Hastelloy parts and FM-rated safety to maintain signal integrity in extreme pressure ranges.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B2 Panel Bracket
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B2KCL4M5
Rosemount 2051CG3F33A1AH3B1K5L4M5 resolves corrosive media tracking hurdles in FM hazardous zones through traditional bracket hardware and Fieldbus integration to ensure high-fidelity signal precision.
- Measurement Type: Range 3 Gage (±1000 inH2O)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B1 Traditional Bracket
- Stability Rating: ±0.1% URL for 3 years
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B2L4M5
Rosemount 2051CG5F33A1AH3B2L4M5 resolves extreme pressure monitoring hurdles through panel-mount traditional brackets and Fieldbus distributed control to maintain high-pressure gage signal integrity.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.075% of span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B2 Traditional Bracket (Panel)
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B3I1L4M5
Rosemount 2051CG5F33A1AH3B3I1L4M5 eliminates high-pressure gage drift in aggressive environments through flat-mounted components and Hastelloy wetted parts to ensure robust ATEX Fieldbus diagnostics.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B3 Flat Bracket
- Power Supply: 9–32 Vdc (Bus)
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B3K5L4M5
Rosemount 2051CG5F33A1AH3B3K5L4M5 optimizes extreme high-pressure gage tracking through flat-mounted hardware and Hastelloy components to deliver smart Fieldbus diagnostics in FM-regulated zones.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276
- Mounting: B3 Flat Bracket
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B3KCL4M5
Rosemount 2051CG3F33A1AH3B2K5L4M5 optimizes aggressive environment monitoring via panel-mounted brackets and FM explosion-proof compliance to deliver reliable mid-range Fieldbus signal integrity.
- Measurement Type: Range 3 Gage (±1000 inH2O)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B2 Panel Bracket
- Power Supply: 9–32 Vdc (Bus)
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B3L4M5
Rosemount 2051CG5F33A1AH3B3L4M5 eliminates high-pressure sensing drift in aggressive media via flat-profile pipe mounting and Hastelloy wetted parts to ensure robust Fieldbus diagnostics.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.075% of span
- Wetted Materials: Hastelloy C-276 Diaphragm
- Mounting: B3 Traditional Bracket (Flat)
- Power Supply: 9–32 Vdc (Bus)
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B4I1L4M5
Rosemount 2051CG5F33A1AH3B4I1L4M5 eliminates extreme high-pressure monitoring drift via Coplanar bracket integration and ATEX intrinsic safety to maintain high-fidelity Fieldbus diagnostics.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276
- Mounting: B4 Coplanar Bracket
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B4K5L4M5
Rosemount 2051CG5F33A1AH3B4K5L4M5 resolves extreme high-pressure monitoring bottlenecks through Coplanar flange hardware and FM safety ratings to ensure reliability in US-regulated Fieldbus networks.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276
- Mounting: B4 Coplanar Bracket
- Certification: US FM K5
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B4KCL4M5
Rosemount 2051CG5F33A1AH3B4KCL4M5 optimizes extreme high-pressure monitoring through Coplanar Fieldbus integration and Hastelloy wetted parts to maintain signal integrity in FM/CSA certified areas.
- Measurement Type: Range 5 Gage (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Hastelloy C-276
- Mounting: B4 Coplanar Bracket
- Communication: FOUNDATION Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1AH3B4L4M5
Rosemount 2051CG5F33A1AH3B4L4M5 resolves extreme high-pressure monitoring hurdles through Hastelloy wetted parts and FOUNDATION Fieldbus architecture to maintain distributed control network integrity.
- Measurement Type: Gage Pressure
- Accuracy Statement: ±0.065% of Span
- Measurement Range: ±2000 psi
- Wetted Materials: Hastelloy C-276
- Mounting: B4 Coplanar Bracket
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1JH3B1I1L4
Rosemount 2051CG5F33A1JH3B1I1L4 overcomes industrial high-pressure gage tracking hurdles via traditional pipe mounting and Alloy C-276 construction for robust digital synchronization.
- Measurement Type: Range 5 Gage Pressure (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1JH3B1K5L4
Rosemount 2051CG5F33A1JH3B1K5L4 resolves industrial high-pressure gage tracking drift through traditional pipe mounting and dual hazardous certifications to ensure robust signal integrity in corrosive Fieldbus loops.
- Measurement Type: Range 5 Gage Pressure (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1JH3B1KCL4
Rosemount 2051CG5F33A1JH3B1KCL4 resolves industrial high-pressure gage tracking hurdles via traditional pipe mounting and Fieldbus communication for robust digital precision in corrosive process streams.
- Measurement Type: Range 5 Gage Pressure (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1JH3B1L4
Rosemount 2051CG5F33A1JH3B1L4 resolves industrial high-pressure sensing drift in safe-area plant zones via traditional pipe mounting and corrosive-resistant construction to ensure robust plant synchronization.
- Measurement Type: Range 5 Gage Pressure (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CG – 2051CG5F33A1JH3B2I1L4
Rosemount 2051CG5F33A1JH3B2I1L4 eliminates high-pressure industrial gage hurdles through panel-mounted hardware and high-durability sensors for reliable digital diagnostics in corrosive streams.
- Measurement Type: Range 5 Gage Pressure (±2000 psi)
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B2 Traditional Panel Bracket
- Stability Rating: ±0.1% URL for 3 years
$2,304.00