Rosemount 2051CD – 2051CD1F22A1JH3B1K5L4
Rosemount 2051CD1F22A1JH3B1K5L4 eliminates low-draft tracking drift through traditional mounting and FM safety compliance to ensure native digital control in standard industrial Fieldbus loops.
- Measurement Type: Differential Pressure (DP)
- Accuracy Statement: ±0.1% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting: B1 Traditional Mounting Bracket
- Stability Rating: ±0.1% URL for 3 years
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD1F22A1JH3B1KCL4
Rosemount 2051CD1F22A1JH3B1KCL4 overcomes industrial low-draft DP monitoring hurdles via traditional bracket hardware and Fieldbus integration to ensure high-fidelity corrosive media tracking.
- Measurement Type: Range 1 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD1F22A1JH3B1KCL4-1
Rosemount 2051CD1F22A1JH3B1KCL4-1 resolves mid-range DP tracking hurdles in hazardous plant zones via traditional pipe mounting and Fieldbus communication to maintain long-term signal stability.
- Measurement Type: Range 1 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B1 Traditional 2-in Pipe Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD1F22A1JH3B2K5L4
Rosemount 2051CD1F22A1JH3B2K5L4 resolves low-draft industrial sensing hurdles via panel-mounted brackets and FM-rated safety to deliver advanced digital Fieldbus diagnostics in volatile areas.
- Measurement Type: Differential Pressure (DP)
- Accuracy Statement: ±0.1% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting: B2 Traditional Panel Bracket
- Power Supply: 9–32 Vdc (Bus-Powered)
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD1F22A1JH3B2KCL4
Rosemount 2051CD1F22A1JH3B2KCL4 optimizes corrosive low-draft sensing through panel-mounted bracket architecture and multi-standard hazardous certifications to deliver robust Fieldbus diagnostics.
- Measurement Type: Range 1 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B2 Traditional Panel Bracket
- Power Supply: 9–32 Vdc (Bus)
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD1F22A1JH3B3K5L4
Rosemount 2051CD1F22A1JH3B3K5L4 overcomes low-draft measurement bottlenecks in FM hazardous zones through flat-mounted hardware and standard 316L SST construction for Fieldbus plant integration.
- Measurement Type: Differential Pressure (DP)
- Accuracy Statement: ±0.1% of Span
- Wetted Materials: 316L SST Diaphragm
- Mounting: B3 Traditional Flat Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00
Rosemount 2051CD – 2051CD1F22A1JH3B3KCL4
Rosemount 2051CD1F22A1JH3B3KCL4 overcomes low-draft DP monitoring drift in hazardous areas through flat-mounted hardware and FOUNDATION Fieldbus integration to ensure precise signal tracking.
- Measurement Type: Range 1 Differential Pressure
- Accuracy Statement: ±0.065% of Span
- Wetted Materials: Alloy C-276 Diaphragm
- Mounting Hardware: B3 Traditional Flat Bracket
- Communication Protocol: FOUNDATION™ Fieldbus
$2,304.00
$2,304.00