Dwyer OP Orifice Plate Flowmeter 14in 20inH2O – OP-P-1
Dwyer OP-P-1 Orifice Plate Flowmeter Metrology Specs
| Brand | Dwyer Instruments |
| Model SKU | OP-P-1 (Size P1 Orifice Package) |
| Country of Origin | United States |
| Measurement Principle | Differential Pressure (Corner Tap Configuration) |
| Line Size | 14-inch Line (4.000" Bore Diameter) |
| Beta Ratio (β) | 0.30 |
| Material | Stainless Steel Plate with Carrier Ring & Integral Gaskets |
| Metering Taps | Built-in 1/4" Female NPT Standard |
| Capacity (Water) | 244.14 GPM @ 20" d.p. W/C |
| Capacity (Air) | 2625.81 SCFM @ 100 psig (20" d.p. W/C) |
| Warranty Period | 1 Year (Standard Manufacturer Warranty) |
| Industrial Application | Low-range flow measurement for 14" pipelines using standard flanges. |